check engine RENAULT SCENIC 2013 J95 / 3.G Electronic Parking Brake Workshop Manual

Page 8 of 115

37B-8
MR-372-J84-37B000$144.mif
V11
37B
ELECTRONIC PARKING BRAKE
Fault finding – System operation
PRESENTATION OF THE PARKING BRAKE:
The electronic parking brake provides the following functions:
– keeps the vehicle stationary when stopped (parking brake).
– 'dynamic' emergency brake (if the main brakes fail).
– automatic braking force adjustment according to the slope (adapted application),
– electronically-assisted parking brake application when the engine is stopped (depending on configuration),
– easy start with electronically-assisted parking brake release (depending on configuration),
– manual application and release by pulling on the lever.
SYSTEM COMPONENTS AND OPERATION:
The system consists of the following components:
●Control lever with brake on indicator light.
– For applying and releasing the parking brake.
●Control unit (computer) housing an electric motor, the brake cable hooks, angle sensor and force sensor.
–The angle sensor controls locking according to the angle of the slope.
–The force sensor checks and corrects the force applied to the brakes.
●Clutch pedal position sensor to help with pulling away.
– Informs the computer of the vehicle's clutch position (the position of the pedal enables the torque necessary for
vehicle movement to be obtained).
●Tw o mechanical cables
– Convey the mechanical force to the rear brakes.
●Emergency control cable (in the central storage compartment on the LAGUNA, VEL SATIS and ESPACE and in
the boot on the SCENIC).
– Enables the rear brakes to be released in the event of the battery or parking brake failing.
●Warning lights and symbol on the instrument panel.
– Indicate application, releasing and any faults on the parking brake.
Note:
The parking brake cable play compensation is performed automatically by the control unit.
FPA
Vdiag No.: 0C, 04, 08,
0D, 11
MR-372-J84-37B000$144.mif

Page 11 of 115

37B-11
MR-372-J84-37B000$144.mif
V11
ELECTRONIC PARKING BRAKE
Fault finding – System operation
FPA
Vdiag No.: 0C, 04, 08,
0D, 11
37B
WARNING LIGHT MANAGEMENT
Indications of a level 1 fault:
–Check Parking Brake message on the instrument panel display.
–orange warning light (P in a triangle) on the instrument panel comes on.
–SERVICE warning light comes on.
Indications of a level 2 fault:
–Parking brake defective message on the instrument panel display.
–1-second audible warning (from the instrument panel),
–orange warning light (P in a triangle) on the instrument panel comes on.
–SERVICE warning light comes on,
–Red indicator light (brake pad light) on the instrument panel comes on.
– parking brake control lever indicator light flashes.
Warning occurs:
– when the door is opened and a gear is engaged on an automatic transmission,
– when the vehicle is moving, despite the parking brake being applied,
– when the door is opened, with the engine running and the parking brake released,
– when the door is opened, with the engine stopped and the parking brake released, Note:
When the lever warning light stops flashing, the instrument panel message disappears. If the system has a level 2
fault, whenever the lever is used, the indicator light on the lever starts flashing again and the fault message
reappears.

Page 16 of 115

37B-16
MR-372-J84-37B000$360.mif
V11
37B
ELECTRONIC PARKING BRAKE
Fault finding – Configurations and programming
CONFIGURATIONS:
Two functions can be turned off by configuration: assisted application and release.
Special note:
Assisted application and release are configured by default when a new computer is initialised. This configuration is
accessible in the log book.
To carry out configuration, select the diagnostic tool's Repair mode menu.
CF007 Vehicle configuration
This configuration turns electronic parking brake application on or off when the engine is stopped.
In cold countries or regions, assisted braking should preferably be inhibited to avoid brake cables becoming frozen
in the applied position.
– Select the type of configuration:
–NORMAL (with assisted braking when the engine is stopped).
–COLD CLIMATE (without assisted braking when the engine is stopped).
– Confirm the operation.
– Make sure the configuration has been properly entered by reading configuration LC009 Vehicle
configuration.
– Make sure the assisted braking function works.
PROGRAMMING:
– Refer to the configuration check.
Note:
When a new computer is initialised, the angle sensor is calibrated by running command VP011 Computer
calibration and initialising.
FPA
Vdiag No.: 0C, 04, 08,
0D, 11
MR-372-J84-37B000$360.mif

Page 23 of 115

37B-23
MR-372-J84-37B000$504.mif
V11
ELECTRONIC PARKING BRAKE
Fault finding – Interpretation of faults
FPA
Vdiag No.: 0C, 04, 08,
0D, 11
37B
DF015
CONTINUED
Clutch pedal position sensor connector: 1057Electronic parking brake computer connector:
1217
Track 1
Track 2
Track 3Track E4
Track E3
Track E2
Repair if necessary.
Disconnect the clutch pedal position sensor connector to check, with the ignition switched on and the electronic
parking brake computer connector connected, the presence of a 5 volt supply, by measuring between tracks 1
and 3 of the sensor (+ 5 V on track 1 and earth on track 3).
If the 5 V supply is not present and the connections previously checked are correct, contact the Techline.
With the clutch pedal position sensor connector disconnected, measure the sensor resistance between tracks 1
and 3 of the sensor.
Replace the sensor if its resistance is not 5200  ± 520 .
If the fault is still present, contact the Techline.
1. DEF; 2. DEF
NOTESConditions for applying the fault finding procedure to
a stored fault:
Engine at idle speed, and gear engaged for 5 seconds.
Check the operation of statuses ET016 Manual gearbox gear lever position and ET017 Reverse gear
engaged and the absence of any incorrect contacts.
If not correct, check the operation of the gearbox sensor.
Check that the clutch pedal position sensor is fitted correctly: the "arm" of the potentiometer should be inserted
correctly into its mounting lug (neither above nor below).
Using the diagnostic tool, display parameter PR006 Clutch pedal position on the main data screen (see the
conformity check values).
Check the conformity of the pedals.
If the fault persists, contact the Techline.
AFTER REPAIRIf the computer has been replaced (at the request of the Techline), initialise the
electronic parking brake computer (see Replacement of components).
Issue several braking and release commands to confirm the repair.
Deal with any other faults.

Page 31 of 115

37B-31
MR-372-J84-37B000$504.mif
V11
ELECTRONIC PARKING BRAKE
Fault finding – Interpretation of faults
FPA
Vdiag No.: 0C, 04, 08,
0D, 11
37B
DF035
PRESENT
OR
STOREDUNDERVOLTAGE
1. DEF: Insufficient feed voltage during the command
NOTESPriority in the event of a number of faults:
Deal with fault DF055 Battery undervoltage first if it is present or stored.
Conditions for applying the fault finding procedure to a stored fault:
Apply this fault finding procedure if the fault reappears after the ignition has been
switched off and on again (+ forced after ignition feed: see Introduction) and an
application or release request using the control lever.
Special notes:
This fault is a power supply fault and does not usually stem from the electronic
parking brake computer.
This fault does not indicate computer feed undervoltage but a significant drop in
voltage to the parking brake motor while the command is being issued.
Only for Vdiag 08, 0C and 0D:
If there is a stored fault, refer to the statuses and parameters when it appears.
Explanation of counters: see Introduction.
If the fault is stored and PR018 = 0 and PR022 > 25, clear the fault:
do not take this fault into account.
Disconnect the electronic parking brake computer connector to check the conformity of the supplies and to
check the insulation, continuity and the absence of interference resistance on the following connections:
Electronic parking brake computer connector
track H4
(except Laguna II, Vel Satis and Espace IV)
track G4+12V
track H2
(except Laguna II, Vel Satis and Espace IV)
track G2earth
Repair if necessary (see the vehicle wiring diagram).
Apply the brake and then release it (engine running) to check that during the command the voltage measured at
the fuse does not drop below 10.5 V.
Make the repairs necessary for the parking brake computer electrical supply to be correct (equal to the battery
voltage).
If the fault persists, contact the Techline.
AFTER REPAIRIf the computer has been replaced (at the request of the Techline), initialise the
electronic parking brake computer (see Replacement of components).
Issue several braking and release commands to confirm the repair.
Deal with any other faults.
FPA_V0C_DF035/FPA_V04_DF035/FPA_V08_DF035/FPA_V0D_DF035/FPA_V11_DF035

Page 54 of 115

37B-54
MR-372-J84-37B000$504.mif
V11
ELECTRONIC PARKING BRAKE
Fault finding – Interpretation of faults37B
DF049
PRESENT
OR
STOREDBRAKING
1. DEF: Inconsistent braking value
2. DEF: Normal brake application value not reached
3. DEF: Normal brake release value not reached
4. DEF: Insufficient braking force
NOTESConditions for applying the fault finding procedure to a stored fault:
The fault is declared present after:
– a braking command is issued on a slope.
Priorities when dealing with a number of faults:
Deal with faults: DF046 Brake motor / cables connection, DF050 Mechanical
seizure, DF035 Undervoltage, DF058 Parking brake motor current and DF055
Battery undervoltage first if they are present or stored.
Check that the parking brake mechanical tensioning line is correct:
– that the parking brake cables are fitted correctly (refer to the repair procedure),
– that the parking brake cables are in good condition (not seized or deteriorated),
– that the rear brake callipers are correct, in good condition and operating correctly,
– that the rear brake pads are correct and in good condition.
Carry out the necessary repairs.
Using the diagnostic tool statuses screen, display parameter PR003 Slope value.
If the value displayed is not 0 degrees (± 1) on level ground, carry out slope initialisation again (actuator control
mode menu).
Using the diagnostic tool parameters screen, display the following parameters: PR005 Force setpoint and PR004
Measured force value. These must show the various values recorded in the conformity check.
Clear the fault, switch off the ignition for 5 minutes (vehicle doors and windows closed), switch the ignition back
on and repeat a braking command on a slope.
If the fault reappears, switch off the ignition and disconnect the computer supply fuse (fuse F23 of the engine fuse
box, refer to the wiring diagram) for approximately 1 minute.
Reconnect the fuse, switch the ignition on and establish dialogue with the computer. Apply the brake to check
whether the fault recurs.
If the fault reappears despite the above tests, or if the parameter values are not within conformity check
tolerances while the brake is applied, then contact your Techline.
AFTER REPAIRClear the fault memory.
Follow the instructions to confirm repair.
If the computer has been replaced (at the request of the Techline), initialise the
electronic parking brake computer (see Replacement of components).
Issue several braking and release commands to confirm the repair.
Deal with any other possible faults.
FPA
Vdiag No.: 04
FPA_V04_DF049

Page 62 of 115

37B-62
MR-372-J84-37B000$504.mif
V11
ELECTRONIC PARKING BRAKE
Fault finding – Interpretation of faults
FPA
Vdiag No.: 0C, 04, 08,
0D, 11
37B
DF054
PRESENT
OR
STOREDBATTERY VOLTAGE TOO HIGH
1. DEF: Battery voltage too high
NOTESPriorities when dealing with a number of faults:
Deal first with faults DF003 (1.DEF; 2.DEF), DF004, DF028, DF029, DF041, DF042,
DF043, DF050, DF057, DF058 and DF073.
Conditions for applying the fault finding procedure to a stored fault:
Apply this fault finding procedure if the fault appears as present again after the ignition
has been switched on
(forced + after ignition feed, see Introduction).
Special notes:
The fault does not usually come from the electronic parking brake computer.
This fault appears as present if the computer supply voltage is greater than 16.5 V,
and becomes stored when the voltage goes back down below 15.7 V.
Note:
Using another battery for a boost when starting may trigger this fault.
Only for Vdiag 08, 0C and 0D.
If there is a stored fault, refer to the statuses and parameters when it appears.
Explanation of counters: see Introduction.
If the fault is stored and PR018 = 0 and PR022 > 25, clear the fault:
do not take this fault into account.
Check the charging circuit: the alternator should not supply a voltage of less than + 12 V or greater than + 14.4 V
(engine at idle speed).
Check the alternator and the regulator.
Carry out the necessary repairs.
If the fault is still present, check that no electrical system using the same supply fuse as the electronic parking
brake computer is faulty.
If the fault persists, contact the Techline.
AFTER REPAIRIf the computer has been replaced (at the request of the Techline), initialise the
electronic parking brake computer (see Replacement of components).
Issue several braking and release commands to confirm the repair.
Deal with any other faults.
FPA_V0C_DF054/FPA_V04_DF054/FPA_V08_DF054/FPA_V0D_DF054/FPA_V11_DF054

Page 64 of 115

37B-64
MR-372-J84-37B000$504.mif
V11
ELECTRONIC PARKING BRAKE
Fault finding – Interpretation of faults
FPA
Vdiag No.: 0C, 04, 08,
0D, 11
37B
DF055
CONTINUED
2. DEF
NOTESSpecial notes:
This fault is generated after the automatic parking brake is
switched on whilst driving or following an internal reset.
With the anti-lock braking system, this detection is active at
> 0.6 mph (> 1 km/h), otherwise the multiplex signal
emitted by the injection computer must be 1.
Note:
The driver is only informed of this fault after 16 successive
detections.
This fault may be due to battery disconnections or vehicle
supply faults, in which case it is associated with fault 1.DEF
(battery voltage too low) dealt with previously.
If the frequency counter (PR016) > 3 and if the onboard network (battery, wiring) analysis does not bring up any
present or stored fault under battery voltage, contact the Techline.
Check that the battery, battery - starter - alternator connection lead, battery earth - chassis lead and the chassis
earth - engine and transmission assembly lead are in good condition.
Repair if necessary.
Check the charging circuit: the alternator should not supply a voltage of less than + 12 V or greater than + 14.4 V
(engine at idle speed).
Carry out the necessary repairs.
track H4
(except Laguna II, Vel Satis and Espace IV)
track G4+12V
track H2
(except Laguna II, Vel Satis and Espace IV)
track G2earth
Repair if necessary (see the vehicle wiring diagram).
If the fault is still present, check that no electrical system using the same supply fuse as the electronic parking
brake computer is faulty.
If the fault persists, contact the Techline.
AFTER REPAIRIf the computer has been replaced (at the request of the Techline), initialise the
electronic parking brake computer (see Replacement of components).
Issue several braking and release commands to confirm the repair.
Deal with any other faults.

Page 69 of 115

37B-69
MR-372-J84-37B000$504.mif
V11
ELECTRONIC PARKING BRAKE
Fault finding – Interpretation of faults37B
DF059
CONTINUED
Use the diagnostic tool to carry out a multiplex system test.
This check ensures that the various multiplex system connections are correct and finds any faulty segments.
Carry out any necessary repairs.
If the multiplex network test did not find the faulty connection, carry out a conformity check to check that the
status from the Protection and Switching Unit computer is present and correct (ET016, PR015, PR017).
Check the gearbox contacts.
If the status and parameters shown here are not correct, carry out fault finding on the Protection and Switching
Unit (see 87G, Engine compartment connection unit).
If the fault is still present, disconnect the Protection and Switching Unit computer connector to check that the
connector and its clips (terminals) are in good condition, especially the multiplex track clips (see the wiring
diagram of the Protection and Switching Unit fitted to the vehicle).
Replace the clips if necessary.
If the fault persists, contact the Techline.
AFTER REPAIRIf the computer has been replaced (at the request of the Techline), initialise the
electronic parking brake computer (see Replacement of components).
Issue several braking and release commands to confirm the repair.
Deal with any other faults.
FPA
Vdiag No.: 0C, 08, 0D,
11

Page 78 of 115

37B-78
MR-372-J84-37B000$576.mif
V11
FPA
Vdiag No.: 0C, 04, 08,
0D, 11ELECTRONIC PARKING BRAKE
Fault finding – Conformity check37B
SUB-FUNCTION: AUTOMATIC APPLICATION
NOTESOnly carry out this conformity check after carrying out a complete check using the
diagnostic tool.
Application conditions: ignition on (forced + after ignition, see Introduction)
Note:
The interpretation of these statuses and parameters is only valid with the
ignition switched on, the statuses and parameters displayed in blue on the
diagnostic tool is information supplied by other computers, which are transmitted via
the multiplex network. If these variables display inconsistent values, check that the
multiplex system test has not shown up any faulty connections. Repair the faulty
multiplex connections before looking for a possible problem with the signals.
Each sub-function in this test is associated with a Fault finding chart.
Special notes
The diagnostic tool may display the message Computer busy when displaying
statuses and parameters. This message is displayed when the parking brake is
applying or releasing the brake, because the computer gives priority to controlling the
motor before transmitting variables. If this message is displayed, exit the current
screen and then return to it.
Order FunctionParameter or Status
Checked or ActionDisplay and notes Fault finding
1Assisted
braking
configurationET022:Automatic
braking
configurationWITH or WITHOUTDepending on the customer's
request, the electronic parking
brake computer may be
configured WITH or WITHOUT
assisted braking when the
engine stops. Refer to the
interpretation of status ET022
Automatic braking
configuration.
2Computer
electrical supplyET001:+ After ignition
feedIgnition off: ABSENT
Ignition on: PRESENTIn the event of a fault on this
status, refer to the interpretation
of status ET001: + after ignition
feed.
3EnginePR015:Engine speed0rpmIn the event of a fault with this
parameter and these statuses,
make sure that the injection
computer is in fact sending
signals (absence of faults DF036
No injection multiplex
transmission and DF052
Multiplex network).
If the fault is still present, run
fault finding on the injection
computer (see 13B, Diesel
injection or 17B, Petrol
injection). ET019:EngineSTOPPED
Other possibilities
depending on the
operating status of the
engine:
RUNNING
- UNDER STARTER
- STALLED

Page:   1-10 11-20 next >